PUMP OPERATOR'S PANEL MANUAL PRIMER HANDLE REPLACEMENT - Continued
PUMP OPERATOR'S PANEL MOMENTARY TOGGLE SWITCH REPLACEMENT - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 3 Page Navigation
  128    129    130    131    132  133  134    135    136    137    138  
img
. .
DRAFT
TM 5-4210-249-13&P-3
0330
FIELD LEVEL MAINTENANCE
PUMP OPERATOR'S PANEL MOMENTARY TOGGLE SWITCH REPLACEMENT
INITIAL SETUP:
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Tools and Special Tools
References
Tool Kit, General Mechanic's: Automotive
WP 0615, Fig. 56
(WP 0622, Item 27)
Equipment Conditions
Materials/Parts
Batteries disconnected (TM 9-2320-325-14&P)
Adhesive, RTV 732 (WP 0625, Item 2)
Pump operator's panel housing
Tags, Identification (WP 0625, Item 51)
opened (WP 0325)
REMOVAL
TFFT00598
NOTE
Pump engine, tank-to-pump, pump cooler, foam tank, and foam system momentary toggle
switches are removed the same way.
Pump cooler momentary toggle switch has six wires.
Tag and mark wires prior to removal to ensure proper installation.
1.
Remove three screws (1) and wires (2) from pump engine momentary toggle switch (3).
NOTE
Note position of momentary toggle switch and wires prior to removal to ensure proper
installation.
2.
Remove nut (4), washer (5), and pump engine momentary toggle switch (3) from pump operator's panel (6).
END OF TASK