DRAFT
TM 5-4210-249-13&P-3
FIELD LEVEL MAINTENANCE
AUDIO ALARM REPLACEMENT
INITIAL SETUP:
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Tools and Special Tools
References
Tool Kit, General Mechanic's: Automotive
WP 0615, Fig. 56
(WP 0622, Item 27)
Equipment Conditions
Materials/Parts
Batteries disconnected (TM 9-2320-325-14&P)
Tags, Identification (WP 0625, Item 51)
Pump operator's panel housing opened
REMOVAL
TFFT00316
NOTE
Both audio alarms are removed the same way.
1.
Disconnect connector (1).
2.
Remove retainer (2) and audio alarm (3) from pump operator's panel (4).
END OF TASK
0319-1