DRAFT
TM 5-4210-249-13&P-3
0317
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
TFFT01263B
WARNING
ICON 30, 44, 27
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful
vapors, and are harmful to skin and clothing. To avoid injury or death, keep away
from open fire and use in well-ventilated area. If adhesive, solvent, or sealing
compound gets on skin or clothing, wash immediately with soap and water.
NOTE
Adhesive is applied to mating surface of decal. Do not apply adhesive to area of decal
that will cover tops of screws.
3.
Apply adhesive to decal (7).
4.
Install decal (7) on pump discharge pressure gauge (2).
NOTE
Perform Step (5) for cab instrument panel gauge only.
5.
Install toggle switch guard (5) on cab instrument panel (6) with two washers (4) and screws (3).
6.
Connect cab instrument panel pump discharge pressure gauge (2) to connector (1).
END OF TASK
FOLLOW-ON MAINTENANCE
1.
Close pump operator's panel housing (if required) (WP 0325)
2.
Install cab instrument panel A (if required) (WP 0311)
END OF TASK
END OF WORK PACKAGE
0317-4