• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
WATER TANK LOW LEVEL SWITCH REPLACEMENT
WATER TANK LOW LEVEL SWITCH REPLACEMENT - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 3 Page Navigation
  40    41    42    43    44  45  46    47    48    49    50  
img
DRAFT
TM 5-4210-249-13&P-3
0302
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
TFFT01187
NOTE
Tag and mark wires and connectors prior to removal.
3.
Disconnect two connectors (5).
4.
Loosen five screws (6) and remove five wires (7) from junction box (4).
5.
Remove collar (8), grommet (9), and cable (10) from fitting (11).
6.
Remove fitting (11) from temperature sender (3).
7.
Loosen locknut (12) and remove temperature sender (3) from water tank (13).
END OF TASK
INSTALLATION
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
WARNING
ICON 30, 44, 27
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful
vapors, and are harmful to skin and clothing. To avoid injury or death, keep away
from open fire and use in well-ventilated area. If adhesive, solvent, or sealing
compound gets on skin or clothing, wash immediately with soap and water.
1.
Apply sealing compound to threads of temperature sender (3).
0302-2