DRAFT
TM 5-4210-249-13&P-3
0303
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
TFFT2518
2.
Disconnect water tank side fill valve connector (5) from pump house power distribution wire harness
connector (6).
3.
Remove two locknuts (7), U-bolt (8), and cradle (9) from bracket (10) and pipe (11). Discard locknuts.
NOTE
Note position of gaskets and water tank side fill valve prior to removal to ensure proper
installation.
4.
With the aid of an assistant, remove eight screws (12), lockwashers (13), washers (14), three gaskets (15),
(16), and (17), pipe (11), and water tank side fill valve (18) from water tank (19). Discard lockwashers and
gaskets.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
0303-2