3.
Install mounting plate (58) on control box (15) with four locknuts (57).
4.
Install two relays (37) and (24) on control box (15).
5.
Install control box (15) on vehicle with four washers (56), lockwashers (55), and screws (54).
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
TFFT01672
6.
Position six wires (51), (48), (43), (39), (30), and (26) in control box (15) and tighten strain relief (53).
7.
Install two wires (52) and (51) on relay (37) and tighten screw (50).
8.
Install two wires (49) and (48) on relay (37) and tighten screw (47).
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
TFFT01677
9.
Position four wires (42), (40), (36), and (11) and elbow (46) in control box (15) and tighten nut (45) on
elbow (46).
10. Install two wires (43) and (42) on contactor (44) and tighten screw (41).
11. Install two wires (40) and (39) on relay (37) and tighten screw (38).
12. Install two wires (36) and (35) on relay (37) and tighten screw (34).