DRAFT
TM 5-4210-249-13&P-3
FIELD LEVEL MAINTENANCE
WATER TANK HEATER CONTROL BOX REPLACEMENT
INITIAL SETUP:
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Tools and Special Tools
References
Tool Kit, General Mechanic's: Automotive
WP 0615, Fig. 54
(WP 0622, Item 27)
Equipment Conditions
Materials/Parts
Water pump engine OFF (WP 0022)
Tags, Identification (WP 0625, Item 51)
Batteries disconnected (TM 9-2320-325-14&P)
Ties, Cable, Plastic (WP 0625, Item 58)
Lockwasher (1)
Lockwasher (4)
Locknut (4)
Locknut (4)
OPENING WATER TANK HEATER CONTROL BOX
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
WARNING
ICON 2
Turn off main circuit breakers and generator before removing covers on
120/240-volt power distribution panel or receptacles. Failure to comply may result
in damage to equipment or electrical shock to personnel.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
0301-1