WATER TANK HEATER CONTROL BOX REPLACEMENT - Continued
WATER TANK HEATER CONTROL BOX REPLACEMENT - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 3 Page Navigation
  27    28    29    30    31  32  33    34    35    36    37  
img
DRAFT
TM 5-4210-249-13&P-3
0301
CONTACTORS AND MOUNTING STRIP REMOVAL
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
TFFT01666
NOTE
Tag and mark wires prior to removal to ensure proper installation.
1.
Loosen 12 screws (1) and remove 14 wires (2) from two contactors (3) and (4).
NOTE
Contactors are secured on mounting strip with spring loaded lock tabs located on bottom
left corner of contactors. Flat blade screwdriver inserted between lock tabs and contactors
will allow contactors to be released from mounting strip.
2.
Remove two contactors (3) and (4) from mounting strip (5).
3.
Remove timer (6) from mounting strip (5).
NOTE
Note position of retainers on mounting strip prior to removal to ensure proper installation.
4.
Loosen six screws (7) and remove three retainers (8) from mounting strip (5).
5.
Remove two screws (9) and mounting strip (5) from mounting plate (10).
END OF TASK
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -