DRAFT
TM 5-4210-249-13&P-2
FIELD LEVEL MAINTENANCE
WATER PUMP ENGINE BATTERY CABLES REPLACEMENT
INITIAL SETUP:
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
References
Tools and Special Tools
WP 0615, Fig. 25
Tool Kit, General Mechanic's: Automotive
(WP 0622, Item 27)
Equipment Conditions
Materials/Parts
Pump house panels H, I and U
removed (WP 0540)
Sealant, RTV 200 Electrical (WP 0625, Item 47)
Pump house heater electric connectors
Tags, Identification (WP 0625, Item 51)
Ties, Cable, Plastic (WP 0625, Item 58)
Lockwasher (5)
REMOVAL
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
TFFT00886
NOTE
Tag and mark cables prior to removal to ensure proper installation.
Remove cable ties as required.
1.
Remove nut (1), lockwasher (2), and negative battery cable (3) from starter solenoid stud (4). Discard
lockwasher.
0225-1