0225
INSTALLATION
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
WARNING
ICON 30, 44, 27
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful
vapors, and are harmful to skin and clothing. To avoid injury or death, keep away
from open fire and use in well-ventilated area. If adhesive, solvent, or sealing
compound gets on skin or clothing, wash immediately with soap and water.
NOTE
Install cable ties as required.
Apply electrical sealant to all battery cable connections after installing cables.
1.
Install negative battery cable (3) on ground stud (18) with lockwasher (17) and nut (16).
2.
Route negative battery cable (3) to starter motor.
3.
Install two positive battery cables (11) and (7) on battery stud (15) with lockwasher (14) and nut (13).
4.
Install positive battery cable (7) to starter motor pass-through stud (8).
5.
Install positive battery cable (11) on preheat control box (12) with lockwasher (10) and nut (9).
6.
Install positive battery cable (7) on pass-through stud (8) with lockwasher (6) and nut (5).
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -