PUMP HOT ALARM/INDICATOR DOES NOT OPERATE WHEN TESTED OR PUMP OVERHEAT CONDITION (PUMP OPERATOR'S PANEL) - Continued
PUMP HOT ALARM/INDICATOR DOES NOT OPERATE WHEN TESTED OR PUMP OVERHEAT CONDITION (PUMP OPERATOR'S PANEL) - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 2 Page Navigation
  178    179    180    181    182  183  184    185    186    187    188  
img
DRAFT
TM 5-4210-249-13&P-2
0138
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT03694
Step 11.
Turn battery disconnect switch to OFF position (WP 0007). Open pump operator's
panel housing (WP 0325). Disconnect pump operator's panel wire harness pump hot
audio alarm connector (WP 0319). Check for continuity across pump operator's panel
wire harness wire 1405 (blue) from PUMP HOT PUSH TO TEST button, terminal to
pump hot audio alarm connector, terminal A.
If there is no continuity, repair wire 1405 in pump operator's panel wire
harness if repairable (TM 9-2320-325-14&P), or replace pump operator's
panel wire harness (WP 0459).
Step 12.
Check for continuity across pump operator's panel wire harness wire 3895 (black) from
pump hot audio alarm, terminal A to a known good ground.
a.
If there is continuity, replace pump hot audio alarm (WP 0328).
b.
If there is no continuity, repair wire 1405 in pump operator's panel wire
harness if repairable (TM 9-2320-325-14&P), or replace pump
operator's panel wire harness (WP 0459).