PUMP HOT ALARM/INDICATOR DOES NOT OPERATE WHEN TESTED OR PUMP OVERHEAT CONDITION (PUMP OPERATOR'S PANEL) - Continued
PUMP HOT ALARM/INDICATOR DOES NOT OPERATE WHEN TESTED OR PUMP OVERHEAT CONDITION (PUMP OPERATOR'S PANEL) - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 2 Page Navigation
  181    182    183    184    185  186  187    188    189    190    191  
img
DRAFT
TM 5-4210-249-13&P-2
0138
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT03697
Step 15.
Check for continuity across pump operator's panel wire 4085 (red) from primer pump
inline fuse terminal to PUMP HOT PUSH TO TEST button terminal.
If there is no continuity, repair wire 4085 in pump operator's panel wire
harness if repairable (TM 9-2320-325-14&P), or replace pump operator's
panel wire harness (WP 0459).
0138-11