PUMP HOT ALARM/INDICATOR DOES NOT OPERATE WHEN TESTED OR PUMP OVERHEAT CONDITION (PUMP OPERATOR'S PANEL) - Continued
PUMP HOT ALARM/INDICATOR DOES NOT OPERATE WHEN TESTED OR PUMP OVERHEAT CONDITION (PUMP OPERATOR'S PANEL) - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 2 Page Navigation
  174    175    176    177    178  179  180    181    182    183    184  
img
DRAFT
TM 5-4210-249-13&P-2
0138
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT03691
Step 6.
Open pump operator's panel housing (WP 0325). Disconnect wire harness pump
operator's panel wire harness connector. With a test lead set, check for continuity
across wire 1405 (blue) from pump house wire harness thermal relief valve sensor
connector, terminal A to pump house wire harness pump operator's panel wire harness
connector, terminal 2.
a.
If there is continuity, repair wire 1405 in pump operator's panel wire
harness if repairable (TM 9-2320-325-14&P), or replace pump
operator's panel wire harness (WP 0459).
b.
If there is no continuity, repair wire 1405 in pump house wire harness if
repairable (TM 9-2320-325-14&P), or replace pump house wire
harness (WP 0458).
0138-4