PUMP HOT ALARM/INDICATOR DOES NOT OPERATE WHEN TESTED OR PUMP OVERHEAT CONDITION (PUMP OPERATOR'S PANEL) - Continued
PUMP HOT ALARM/INDICATOR DOES NOT OPERATE WHEN TESTED OR PUMP OVERHEAT CONDITION (PUMP OPERATOR'S PANEL) - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 2 Page Navigation
  180    181    182    183    184  185  186    187    188    189    190  
img
DRAFT
TM 5-4210-249-13&P-2
0138
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT03696
Step 14.
Remove driver side crew cab panel (WP 0499). Remove pump house panel
Q (WP 0540). Disconnect main wire harness pump operator's panel wire harness
connector D02. With a test lead set, check for continuity across wire 2773 (red) from
inline fuse terminal to main wire harness pump operator's panel wire harness connector
D02, terminal 16.
If there is no continuity, repair wire 2773 in pump operator's panel wire
harness if repairable (TM 9-2320-325-14&P), or replace pump operator's
panel wire harness (WP 0459).
0138-10