PUMP HOT ALARM/INDICATOR DOES NOT OPERATE WHEN TESTED OR PUMP OVERHEAT CONDITION (PUMP OPERATOR'S PANEL) - Continued
PUMP HOT ALARM/INDICATOR DOES NOT OPERATE WHEN TESTED OR PUMP OVERHEAT CONDITION (PUMP OPERATOR'S PANEL) - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 2 Page Navigation
  177    178    179    180    181  182  183    184    185    186    187  
img
DRAFT
TM 5-4210-249-13&P-2
0138
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT03693
Step 9.
Check for continuity across pump operator's panel wire harness wire 3895 (black) from
PUMP HOT indicator terminal to a known good ground.
a.
If there is continuity, replace PUMP HOT indicator (WP 0326).
b.
If there is no continuity, repair wire 3895 in pump operator's panel wire
harness if repairable (TM 9-2320-325-14&P), or replace pump
operator's panel wire harness (WP 0459).
Step 10.
While pushing pump operator's panel PUMP HOT PUSH TO TEST button, check if
PUMP HOT indicator illuminates (WP 0004).
If PUMP HOT indicator does not illuminate, go to Step 13.
0138-7