DIRECT TANK FILL VALVE DOES NOT OPERATE PROPERLY (AUTO OR MANUAL MODE) - Continued
DIRECT TANK FILL VALVE DOES NOT OPERATE PROPERLY (AUTO OR MANUAL MODE) - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 1 Page Navigation
  686    687    688    689    690  691  692    693    694    695    696  
img
.
DRAFT
TM 5-4210-249-13&P-1
0105
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT02795
Step 25.
Install circuit breaker P1 (WP 0412). Open pump operator's housing (WP 0540).
Disconnect pump operator's panel wire harness direct tank fill valve connector. Turn
battery disconnect switch to ON position (WP 0007). With a test lead set, check for 22
to 28 VDC between pump operator's panel wire harness wire 2314 (red) at direct tank
fill valve wire harness connector, terminal 1 and a known good ground.
If 22 to 28 VDC are not present, repair wire 2314 in pump house power
distribution wire harness if repairable (TM 9-2320-325-14&P), or replace
pump house distribution wire harness and block (WP 0457).
0105-22