DIRECT TANK FILL VALVE DOES NOT OPERATE PROPERLY (AUTO OR MANUAL MODE) - Continued
DIRECT TANK FILL VALVE DOES NOT OPERATE PROPERLY (AUTO OR MANUAL MODE) - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 1 Page Navigation
  670    671    672    673    674  675  676    677    678    679    680  
img
DRAFT
TM 5-4210-249-13&P-1
0105
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT02781
Step 7.
Remove relay P2 (WP 0413). With a test lead set, check for continuity across pump
house power distribution wire harness wire 2328 (green) from relay P2 connector,
terminal 2 to relay P3 connector, terminal 2.
If there is no continuity, replace pump house power distribution wire harness
and block (WP 0457).
0105-6