WATER PUMP ENGINE FAILS TO CRANK FROM PERSONNEL CAB AND PUMP OPERATOR'S PANEL - Continued
WATER PUMP ENGINE FAILS TO CRANK FROM PERSONNEL CAB AND PUMP OPERATOR'S PANEL - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 1 Page Navigation
  356    357    358    359    360  361  362    363    364    365    366  
img
. . .
DRAFT
TM 5-4210-249-13&P-1
0074
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT03511
WARNING
ICON 3
Remove rings, wristwatches, neck chains, and any other jewelry before working
around vehicle. Jewelry can catch on equipment and cause serious injury. Jewelry
and tools may short across electrical circuits and cause damage to equipment, or
severe burns or electrical shock to personnel.
Step 7.
Turn battery disconnect switch to OFF position (WP 0007). Connect pump hose wire
harness pump engine wire harness connector. Remove pump house panel
G (WP 0540). Remove pump engine cooling shroud (WP 0248). Turn battery
disconnect switch to ON position (WP 0007). While an assistant puts cab or pump
operator's panel START PUMP ENGINE STOP switch to START position (WP 0022),
check for 22 to 28 VDC between pump engine wire harness starter solenoid signal wire
at pump engine starter solenoid, terminal to a known good ground.
If 22 to 28 VDC are not present, repair wire 4072 in pump engine wire
harness if repairable (TM 9-2320-325-14&P), or replace pump engine wire
harness (WP 0464).
0074-7