WATER PUMP ENGINE FAILS TO CRANK FROM PERSONNEL CAB AND PUMP OPERATOR'S PANEL - Continued
WATER PUMP ENGINE FAILS TO CRANK FROM PERSONNEL CAB AND PUMP OPERATOR'S PANEL - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 1 Page Navigation
  354    355    356    357    358  359  360    361    362    363    364  
img
. . .
DRAFT
TM 5-4210-249-13&P-1
0074
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT03509
WARNING
ICON 3
Remove rings, wristwatches, neck chains, and any other jewelry before working
around vehicle. Jewelry can catch on equipment and cause serious injury. Jewelry
and tools may short across electrical circuits and cause damage to equipment, or
severe burns or electrical shock to personnel.
Step 5.
Turn battery disconnect switch to OFF position (WP 0007). Remove passenger side
crew cab access panel (WP 0499). Remove pump house panel P (WP 0540).
Disconnect pump house wire harness pump engine wire harness connector. Turn
battery disconnect switch to ON position (WP 0007). While an assistant puts cab or
pump operator's panel START PUMP ENGINE STOP switch to START position
(WP 0022), check for 22 to 28 VDC between pump house wire harness wire 4072
(green) at pump house wire harness pump engine wire harness connector, terminal and
a known good ground.
If 22 to 28 VDC are present, go to Step 7.