DRAFT
TM 5-4210-249-13&P-1
0074
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT03506
Step 1.
Turn battery disconnect switch to ON position (WP 0007). Put cab START PUMP
STOP switch to START position (WP 0022). Check if pump engine cranks from cab
position.
If pump engine cranks from cab position, troubleshoot Water Pump Engine
Fails To Crank From Pump Operator's Panel (WP 0076).
Step 2.
Open pump operator's panel (WP 0019). Put pump operator's panel START PUMP
ENGINE STOP switch to START position (WP 0022). Check if pump engine cranks
from pump operator's panel position.
If pump engine cranks from pump operator's panel position, troubleshoot
Water Pump Engine Fails To Crank From Personnel Cab (WP 0075).
0074-2