WATER PUMP ENGINE FAILS TO CRANK FROM PERSONNEL CAB AND PUMP OPERATOR'S PANEL - Continued
WATER PUMP ENGINE FAILS TO CRANK FROM PERSONNEL CAB AND PUMP OPERATOR'S PANEL - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 1 Page Navigation
  359    360    361    362    363  364  365    366    367    368    369  
img
DRAFT
TM 5-4210-249-13&P-1
0074
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT03514
WARNING
ICON 3
Remove rings, wristwatches, neck chains, and any other jewelry before working
around vehicle. Jewelry can catch on equipment and cause serious injury. Jewelry
and tools may short across electrical circuits and cause damage to equipment, or
severe burns or electrical shock to personnel.
Step 11.
Check for 22 to 28 VDC between high amperage cable at pass-through terminal block
to a known good ground.
a.
If 22 to 28 VDC are present, replace pump engine starter high
amperage cable and pass-through terminal block (WP 0368).
b.
If 22 to 28 VDC are not present, replace high amperage cable from
pass-through terminal block to chassis terminal block (WP 0368).
0074-10