TM 5-4210-233-14&P-2
6-49. TORQUE CONVERTER STATOR - Continued
c.
Cleaning and Inspection.
WARNING
Dry cleaning solvent P-D-680 is potentially dangerous. Avoid
repeated and prolonged breathing of vapors and skin contact
with the liquid. Do not use near open flame, arcing equipment
or other ignition sources. Always wear eye protection and
protective clothing. The flash point of P-D-680 is 100 to 138
deg. F (38 to 59 deg. C).
(1)
Clean all parts in dry cleaning solvent (Item 3, Appendix E).
WARNING
Compressed air used for cleaning purposes will not exceed 30
psi (207 kPa). Use only with effective chip guarding and
personal protective equipment, goggles, shield, and gloves.
(2)
Use clean lint free cloth or compressed air to dry parts cleaned with dry cleaning solvent.
(3)
Inspect parts for damage. Replace
damaged parts.
(4)
Coat all parts with lubricating oil (Item 1O,
d. Assembly.
(1)
Position stator (1) on work surface, rear
side upward.
(2)
Install thrust bearing race (2) in stator (1).
(3)
Install stator roller holder against thrust
bearing race (2) so string of stator roller
holder hangs out bottom of stator (1).
CAUTION
Roller springs must be installed as shown in illustration with
center pointing end of spring next to roller.
(4)
Install 10 roller springs (3) and rollers (4) in stator cam pockets (5).
6-269