SYNCHRONOUS AND TIMING REFERENCE SENSOR - Continued
SYNCHRONOUS AND TIMING REFERENCE SENSOR - Continued

Maintenance Manual for Firefighting Truck, 100 Ft Aerial Ladder, 1000 GPM Page Navigation
  132    133    134    135    136  137  138    139    140    141    142  
img
.
TM 5-4210-233-14&P-2
6-28. SYNCHRONOUS AND TIMING REFERENCE SENSOR - Continued
(10)
Insert the SRS/TRS timing tool (Appendix B, Section 111, Item 40) between the double teeth on the
pulse wheel, and the TRS so that the groove at the rear of the tool slides over the teeth in the pulse wheel.
(11) This operation is necessary if the sensor bracket has been loosened from its original mounting position. If
the sensor bracket has not been loosened, go to Step 13. Position the SRS/TRS bracket so that the round
end of the TRS is located in the half moon portion at the front of the timing tool.