CURB SIDE PUMP DISCHARGE MANIFOLD - Continued

Maintenance Manual for Firefighting Truck, 100 Ft Aerial Ladder, 1000 GPM Page Navigation
1  2    3    4    5    6  
img
. . . . . .
TM 5-4210-233-14&P-2
6-2. CURB SIDE PUMP DISCHARGE MANIFOLD
This task covers:
a. Removal
c. Follow-on Maintenance
b. Installation
TOOLS REQUIRED
EQUIPMENT CONDITION
Tool Kit, General Mechanics, Automotive
Main Engine Shutdown (see para 2-12.)
(Appendix B, Section III, Item 1)
APU Shutdown (see para 2-16.)
Batteries Disconnected (see para 4-114.)
MATERIALS/PARTS REQUIRED
Curbside Operators Panel Removed
Tags, Identification (Item 32, Appendix E)
(see para 4-26.)
Gasket (Figure 31, Appendix F)
O-rings (Figure 14, Appendix F)
O-rings (Figure 12, Appendix F)
O-rings (Figure 22, Appendix F)
a. Removal
(1)
Tag and disconnect two drain valve hoses (1).
(2)
Tag and disconnect two pressure gauge hoses (2).
(3)
Remove two roll pins (3) to lift off two sector gears (4).
NOTE
Note position of sector gears to install them correctly during
installation.