PUMP HOUSE ACCESS DOORS REPLACEMENT
PUMP HOUSE ACCESS DOORS REPLACEMENT - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 3 Page Navigation
  1150    1151    1152    1153    1154  1155  1156    1157    1158    1159    1160  
img
DRAFT
TM 5-4210-249-13&P-3
0538
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
TFFT00145A
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
WARNING
ICON 26
Wear goggles and use care when replacing spring. Spring is under tension and can
act as a projectile when released. Failure to comply may result in injury to
personnel.
NOTE
Note position of spring prior to removal to ensure proper installation.
4.
Bend two tabs (10) back, and remove spring (11) from hinge (5).
5.
Remove seal (12) from pump house access door (1).
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
WARNING
ICON 30, 44, 27
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful
vapors, and are harmful to skin and clothing. To avoid injury or death, keep away
from open fire and use in well-ventilated area. If adhesive, solvent, or sealing
compound gets on skin or clothing, wash immediately with soap and water.
6.
Clean seal (12) residue from pump house access door (1) with mineral spirits.
END OF TASK
0538-2