1.
Remove pump house ventilation fan (1) (WP 0416).
2.
Remove two locknuts (2), cushion clips (3), washers (4), screws (5), and wire (6) from pump panel A (7).
Discard locknuts.
3.
Remove support rod (8) from bracket (9).
4.
With the aid of an assistant, remove five locknuts (10), washers (11), screws (12), and pump panel A (7) from
hinge (13). Discard locknuts.
5.
Remove locknut (14) and support rod (8) from bracket (15). Discard locknut.
6.
Remove four locknuts (16), washers (17), washers (18), screws (19), and two brackets (15) form pump
panel A (7). Discard locknuts.
NOTE
Note position of quick release fasteners prior to removal to ensure proper installation.
7.
Remove three screws (20), washers (21), retainers (22), and quick release fasteners (23) from pump
panel A (7).
8.
Remove 16 locknuts (24), washers (25), screws (26), screen (27), and eight locks (28) from pump panel A (7).
Discard locknuts.
9.
Remove seal (29) form pump panel A (7).
NOTE
Perform Steps (10) and (11) if hinge needs to be removed.
10. Remove water pump engine air cleaner assembly (30) (WP 0220).
11. Remove five screws (31) and hinge (13) from pump panel B (32).
12. Remove four rubber seals (33) from screen (27).
END OF TASK
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
0540-3