WATER TANK HEATER CONTROL BOX REPLACEMENT - Continued
WATER TANK HEATER CONTROL BOX REPLACEMENT - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 3 Page Navigation
  30    31    32    33    34  35  36    37    38    39    40  
img
DRAFT
TM 5-4210-249-13&P-3
0301
TERMINAL STRIP COMPONENTS AND MOUNTING STRIP INSTALLATION
1.
Install mounting strip (11) on mounting plate (17) with two screws (16).
NOTE
Terminal strip components are installed from the bottom up.
2.
Install cap (15) on mounting strip (11) with two screws (14).
3.
Install five terminals (13), (8), (7), (6), and (5), fuse block (1), and fuse block cover (12) on mounting strip (11).
4.
Install cap (10) on mounting strip (11) with two screws (9).
5.
Install 13 wires (4) on fuse block (1) and four terminals (8), (7), (6), and (5) and tighten 13 screws (3).
6.
Install fuse (2) on fuse block (1).
7.
Close fuse block (1).
END OF TASK
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
0301-9