DRAFT
TM 5-4210-249-13&P-2
FIELD LEVEL MAINTENANCE
PRIMER VALVE CONTROL SOLENOID(S) REPLACEMENT
INITIAL SETUP:
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Tools and Special Tools
References
Tool Kit, General Mechanic's: Automotive
WP 0615, Fig. 41
(WP 0622, Item 27)
Equipment Conditions
Materials/Parts
Pump house panel A opened (WP 0539)
Compound Sealing (WP 0625, Item 17)
Tags, Identification (WP 0625, Item 51)
Materials/Parts (continued)
Lockwasher (8)
PUMP PRIMER SOLENOID REMOVAL
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
TFFT04148
NOTE
Tag and mark wires prior to removal to ensure proper installation.
1.
Remove nut (1), lockwasher (2), jumperwire 2768 (3), and No. 6 gauge wire (4) from pump primer
2.
Remove nut (6), lockwasher (7), and wire 1590 (8) from pump primer solenoid (5). Discard lockwasher.
3.
Remove nut (9), lockwasher (10), and wire 1640 (11) from pump primer solenoid (5). Discard lockwasher.
4.
Remove nut (12), lockwasher (13), and wire 4064 (14) from pump primer solenoid (5). Discard lockwasher.
0266-1