HYDRAULIC GENERATOR DOES NOT OPERATE PROPERLY - Continued
HYDRAULIC GENERATOR DOES NOT OPERATE PROPERLY - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 2 Page Navigation
  567    568    569    570    571  572  573    574    575    576    577  
img
DRAFT
TM 5-4210-249-13&P-2
0171
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT04592
Step 27.
Check if AC VOLTS display on hydraulic generator digital display is greater than 0 VAC,
with hydraulic generator running.
If AC VOLTS display is greater than 0 VAC, replace hydraulic generator
(WP 0592).
NOTE
Hydraulic generator makes a distinctive sound when it starts. Listen near the hydraulic
generator to determine if the PTO engages and the hydraulic generator starts.
Step 28.
Put GENERATOR PTO switch to disengage then to engage position (WP 0004). Check
if hydraulic generator starts when GENERATOR PTO switch is placed in the engaged
position (WP 0004).
If hydraulic generator does not start, replace hydraulic generator (WP 0592).
0171-14