HYDRAULIC GENERATOR DOES NOT OPERATE PROPERLY - Continued
HYDRAULIC GENERATOR DOES NOT OPERATE PROPERLY - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 2 Page Navigation
  562    563    564    565    566  567  568    569    570    571    572  
img
DRAFT
TM 5-4210-249-13&P-2
0171
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT04517
NOTE
White wire from fuse A to circuit breaker box is covered in red tape inside circuit breaker
box and hydraulic digital display module. Wire from fuse A to POWER ON light is red.
Step 15.
Open hydraulic generator digital display module (WP 0585). Check for continuity
across (white) red wire from circuit breaker 3 to hydraulic digital display module fuse A
socket.
If continuity is not present, replace hydraulic generator digital display
cord (WP 0361).
Step 16.
Check for continuity across red wire from hydraulic generator display module fuse A
socket to POWER ON indicator.
If continuity is not present, replace red wire (TM 9-2320-325-14&P).
0171-9