DRAFT
TM 5-4210-249-13&P-2
0171
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT04514
NOTE
Circuit breaker may be in ON position when tripped. To make sure circuit breaker is not
tripped, reset circuit breaker by switching it to the OFF position then back to ON position.
Step 9.
Reset circuit breakers 1 and 3. Start hydraulic generator (WP 0021). Operate 120 VAC
circuits. Check if circuit breakers 1 and 3 trip.
If circuit breakers 1 and 3 trip, replace circuit breaker (WP 0360).
WARNING
ICON 3
Remove rings, wristwatches, neck chains, and any other jewelry before working
around vehicle. Jewelry can catch on equipment and cause serious injury. Jewelry
and tools may short across electrical circuits and cause damage to equipment, or
severe burns or electrical shock to personnel.
Step 10.
Check the operation of all 120 VAC circuits.
a.
If any 120 VAC circuits work, fault corrected.
b.
If all 120 VAC circuits do not operate, replace hydraulic generator
(WP 0592).
0171-6