DIRECT TANK FILL OPEN INDICATOR DOES NOT ILLUMINATE (PUMP OPERATOR'S PANEL)
DIRECT TANK FILL OPEN INDICATOR DOES NOT ILLUMINATE (PUMP OPERATOR'S PANEL) - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 2 Page Navigation
  40    41    42    43    44  45  46    47    48    49    50  
img
DRAFT
TM 5-4210-249-13&P-2
0129
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT2498
Step 1.
Remove direct tank fill valve cover (WP 0303). Turn battery disconnect switch to ON
position (WP 0007). Open pump operator's panel (WP 0019). While an assistant puts
pump operator's panel DIRECT TANK FILL switch to OPEN position (WP 0004), check
if direct tank fill valve operates to open position.
If direct tank fill valve does not operate to open position, troubleshoot Direct
Tank Fill Valve Does Not Operate Properly (Auto or Manual
Mode) (WP 0105).