DIRECT TANK FILL AUTO INDICATOR DOES NOT ILLUMINATE (PUMP OPERATOR'S PANEL)
DIRECT TANK FILL OPEN INDICATOR DOES NOT ILLUMINATE (PUMP OPERATOR'S PANEL)

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 2 Page Navigation
  38    39    40    41    42  43  44    45    46    47    48  
img
DRAFT
TM 5-4210-249-13&P-2
0128
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT2508
Step 4.
Turn battery disconnect switch to ON position (WP 0007). Put pump operator's panel
DIRECT TANK FILL switch to AUTO position (WP 0004). Check for 22 to 28 VDC at
pump operator's panel wire harness wire 2316 (brown) from DIRECT TANK FILL AUTO
indicator to a known good ground.
a.
If 22 to 28 VDC are present, replace DIRECT TANK FILL AUTO
indicator (WP 0326).
b.
If 22 to 28 VDC are not present, repair wire 2316 in pump operator's
panel wire harness if repairable (TM 9-2320-325-14&P), or replace
pump operator's panel wire harness (WP 0459).
END OF TASK
FOLLOW-ON MAINTENANCE
Remove wheel chocks (TM 9-2320-347-10)
END OF TASK
END OF WORK PACKAGE
0128-5/(6 blank)