DIRECT TANK FILL OPEN INDICATOR DOES NOT ILLUMINATE (PUMP OPERATOR'S PANEL) - Continued
DO NOT MOVE APPARATUS WHEN LIGHT IS ON INDICATOR DOES NOT OPERATE PROPERLY

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 2 Page Navigation
  43    44    45    46    47  48  49    50    51    52    53  
img
DRAFT
TM 5-4210-249-13&P-2
0129
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT2495
Step 4.
Turn battery disconnect switch to ON position (WP 0007). Check for 22 to 28 VDC
between pump operator's panel wire harness wire 2315 (yellow) from pump operator's
panel DIRECT TANK FILL open indicator to a known good ground.
a.
If 22 to 28 VDC are present, replace DIRECT TANK FILL open
indicator (WP 0326).
b.
If 22 to 28 VDC are not present, repair wire 2315 in pump operator's
panel wire harness if repairable (TM 9-2320-325-14&P), or replace
pump operator's panel wire harness (WP 0459).
END OF TASK
FOLLOW-ON MAINTENANCE
Remove wheel chocks (TM 9-2320-347-10)
END OF TASK
END OF WORK PACKAGE
0129-5/(6 blank)