DRAFT
TM 5-4210-249-13&P-2
FIELD LEVEL MAINTENANCE
DIRECT TANK FILL OPEN INDICATOR DOES NOT ILLUMINATE (PUMP OPERATOR'S PANEL)
INITIAL SETUP:
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Tools and Special Tools
Equipment Conditions
Tool Kit, General Mechanic's: Automotive
Water pump engine OFF (WP 0022)
(WP 0622, Item 27)
Engine OFF (TM 9-2320-347-10)
Wheels chocked (TM 9-2320-347-10)
References
TM 9-2320-325-14&P
WP 0004
WP 0007
WP 0019
WP 0105
WP 0303
WP 0325
WP 0326
WP 0327
WP 0459
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
DIRECT TANK FILL OPEN INDICATOR DOES NOT ILLUMINATE (PUMP OPERATOR'S PANEL)
NOTE
Ensure cap is installed tightly on direct tank fill inlet during this procedure. Or, connect
hose to direct tank fill inlet to drain water into appropriate container or to ground. If direct
tank fill valve opens during this procedure, water will discharge from tank uncontrolled.
Valve operations can be checked by observing valve shaft rotation.
Step 1 will ensure that direct tank fill system is operating properly or if fault exists in lamp,
indicator, or wires leading to indicator.
0129-1