DIRECT TANK FILL AUTO INDICATOR DOES NOT ILLUMINATE (PUMP OPERATOR'S PANEL)
DIRECT TANK FILL AUTO INDICATOR DOES NOT ILLUMINATE (PUMP OPERATOR'S PANEL)

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 2 Page Navigation
  35    36    37    38    39  40  41    42    43    44    45  
img
DRAFT
TM 5-4210-249-13&P-2
0128
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT2498
NOTE
Ensure cap is installed tightly on direct tank fill connector during this procedure. Or,
connect hose to direct tank fill connector to drain water into appropriate container or to
ground. If direct tank fill valve opens during this procedure, water will discharge from tank
uncontrolled.
Valve operations can be checked by observing valve shaft rotation.
Step 1 will ensure that direct tank fill system is operating properly or if fault exists in bulb,
indicator, or wires leading to indicator.
Step 1.
Remove direct tank fill valve cover (WP 0303). Turn battery disconnect switch to ON
position (WP 0007). While an assistant puts pump operator's panel DIRECT TANK
FILL switch to OPEN position (WP 0004), check if direct tank fill valve operates to open
position.
If direct tank fill valve does not operate to open position, troubleshoot Direct
Tank Fill Valve Does Not Operate Properly (Auto or Manual
Mode) (WP 0105).
0128-2