PUMP PRIMING SYSTEM DOES NOT OPERATE PROPERLY - Continued
PUMP PRIMING SYSTEM DOES NOT OPERATE PROPERLY - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 1 Page Navigation
  875    876    877    878    879  880  881    882    883    884    885  
img
. .
DRAFT
TM 5-4210-249-13&P-1
0115
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT04177
Step 51.
While an assistant pushes pump operator's panel PUMP PRIME switch (WP 0004),
check for 22 to 28 VDC between pump house wire harness wire 4065 (red) at pump
prime primer valve and a known good ground.
If 22 to 28 VDC are not present, go to Step 53.
Step 52.
Turn battery disconnect switch to OFF position (WP 0007). Disconnect pump house
wire harness wire 4068 (black) from pump prime valve terminal (WP 0267). Check for
continuity across 4068 (black) from wire termination to a known good ground.
a.
If continuity is present, replace pump prime valve (WP 0267).
b.
If continuity is not present, repair 4068 in pump house wire harness if
repairable (TM 9-2320-325-14&P), or replace pump house wire
harness (WP 0458).
0115-29