DRAFT
TM 5-4210-249-13&P-1
0115
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT04170
Step 58.
Open pump house panel A (WP 0539). Check pump prime primer valve manual primer
cable for binding and damage.
If pump prime manual primer cable is binding or damaged, replace pump
prime primer valve manual primer cable (WP 0265).
Step 59.
Check primer pump hose from primer pump to pump prime valve fitting for leaks, kinks,
or damage.
If primer pump hose is not free from leaks, kinks, or damage, replace primer
pump hose (WP 0490).
Step 60.
Check tubing from pump prime valve fitting to pump intake fitting for leaks, kinks, or
damage.
a.
If tubing is free from leaks, kinks, or damage, replace primer pump
(WP 0262).
b.
If tubing is not free from leaks, kinks, or damage, replace tubing
(WP 0490).
0115-33