PUMP PRIMING SYSTEM DOES NOT OPERATE PROPERLY - Continued
PUMP PRIMING SYSTEM DOES NOT OPERATE PROPERLY - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 1 Page Navigation
  872    873    874    875    876  877  878    879    880    881    882  
img
DRAFT
TM 5-4210-249-13&P-1
0115
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT04116
Step 46.
Remove driver side crew cab access panel (WP 0499). Remove pump house panel Q
(WP 0325). Disconnect pump operator's panel wire harness main wire harness
connector DO 2. With a test lead set, check for continuity across pump operator's panel
wire harness wire 2773 (red) from pump operator's panel PUMP PRIMER switch
terminal to pump operator's panel wire harness main wire harness connector DO 2,
terminal 16.
If continuity is not present, repair wire 2773 in pump operator's panel wire
harness if repairable (TM 9-2320-325-14&P), or replace pump operator's
panel wire harness (WP 0459).
0115-26