DRAFT
TM 5-4210-249-13&P-1
0115
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT04170
Step 40.
Open pump house panel A (WP 0539). Check pump prime primer valve manual primer
cable for binding and damage.
If pump prime primer valve manual primer cable is binding or damaged,
replace pump prime primer valve manual primer cable (WP 0265).
Step 41.
Check primer pump hose from primer pump to pump prime primer valve fitting for leaks,
kinks, or damage.
If primer pump hose is not free from leaks, kinks, or damage, replace primer
pump hose (WP 0490).
Step 42.
Check tubing from pump prime primer valve fitting to water pump intake fitting
(WP 0490) for leaks, kinks, or damage.
a.
If tubing is free from leaks, kinks, or damage, replace primer
pump (WP 0262).
b.
If tubing is not free from leaks, kinks, or damage, replace
tubing (WP 0490).
0115-24