PUMP PRIMING SYSTEM DOES NOT OPERATE PROPERLY - Continued
PUMP PRIMING SYSTEM DOES NOT OPERATE PROPERLY - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 1 Page Navigation
  873    874    875    876    877  878  879    880    881    882    883  
img
. . .
DRAFT
TM 5-4210-249-13&P-1
0115
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT04117
Step 47.
Remove skid plate grille (WP 0550). Disconnect main wire harness main 5 connector.
With a test lead set, check for continuity across main wire harness wire 2773 (red), from
main wire harness main 5 connector, terminal 8 to main wire harness pump operator's
panel wire harness connector DO 2, terminal 16.
a.
If continuity is present, repair wire 2773 in pump control wire harness if
repairable (TM 9-2320-325-14&P), or replace cab pump control wire
harness (WP 0443).
b.
If continuity is not present, repair wire 2773 in main wire harness if
repairable (TM 9-2320-325-14&P), or replace main wire
harness (WP 0455).
Step 48.
Prepare vehicle to pump from draft (WP 0025). Pull PUMP PRIME manual priming
cable to closed position (WP 0023). Check if water is drawn to water pump (WP 0025).
If water is not drawn to water pump, go to Step 58.
0115-27