FOAM NOT DELIVERED FROM ALL SYSTEMS (BUMPER TURRET, GROUND SWEEPS, AND MANUAL METERING CONTROLS) OR SYSTEM DOES NOT SHUT OFF - Continued
FOAM NOT DELIVERED FROM ALL SYSTEMS (BUMPER TURRET, GROUND SWEEPS, AND MANUAL METERING CONTROLS) OR SYSTEM DOES NOT SHUT OFF - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 1 Page Navigation
  480    481    482    483    484  485  486    487    488    489    490  
img
. .
DRAFT
TM 5-4210-249-13&P-1
0094
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT03730
Step 30.
Put pump operator's panel FOAM FLUSH switch to OFF position (WP 0004). Put
personnel cab or pump operator's panel FOAM SYSTEM switch to ON position
(WP 0004). Check if foam system indicator illuminates at pump operator's panel or
personnel cab.
If foam system indicator does not illuminate, go to Step 32.
0094-24