FOAM NOT DELIVERED FROM ALL SYSTEMS (BUMPER TURRET, GROUND SWEEPS, AND MANUAL METERING CONTROLS) OR SYSTEM DOES NOT SHUT OFF - Continued
FOAM NOT DELIVERED FROM ALL SYSTEMS (BUMPER TURRET, GROUND SWEEPS, AND MANUAL METERING CONTROLS) OR SYSTEM DOES NOT SHUT OFF - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 1 Page Navigation
  484    485    486    487    488  489  490    491    492    493    494  
img
.
DRAFT
TM 5-4210-249-13&P-1
0094
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT03736
Step 34.
While an assistant puts pump operator's panel FOAM FLUSH switch to ON and OFF
positions (WP 0004), check if foam flush shutoff valve operates to open and closed
position.
If foam flush shutoff valve does not operate to open and closed positions,
replace air line from vehicle air reservoir to shutoff control valve
manifold (WP 0567).