FOAM NOT DELIVERED FROM ALL SYSTEMS (BUMPER TURRET, GROUND SWEEPS, AND MANUAL METERING CONTROLS) OR SYSTEM DOES NOT SHUT OFF - Continued
FOAM NOT DELIVERED FROM ALL SYSTEMS (BUMPER TURRET, GROUND SWEEPS, AND MANUAL METERING CONTROLS) OR SYSTEM DOES NOT SHUT OFF - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 1 Page Navigation
  476    477    478    479    480  481  482    483    484    485    486  
img
. .
DRAFT
TM 5-4210-249-13&P-1
0094
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT3726
WARNING
ICON 3
Remove rings, wristwatches, neck chains, and any other jewelry before working
around vehicle. Jewelry can catch on equipment and cause serious injury. Jewelry
and tools may short across electrical circuits and cause damage to equipment, or
severe burns or electrical shock to personnel.
Step 26.
Turn battery disconnect switch to OFF position (WP 0007). While an assistant holds
pump operator's panel FOAM SYSTEM switch to ON position (WP 0004), check for
continuity across FOAM SYSTEM switch from terminal wire 2816 (red) to terminal wire
2830 (red).
If there is no continuity, replace pump operator's panel FOAM SYSTEM
switch (WP 0330).