FOAM NOT DELIVERED FROM ALL SYSTEMS (BUMPER TURRET, GROUND SWEEPS, AND MANUAL METERING CONTROLS) OR SYSTEM DOES NOT SHUT OFF - Continued
FOAM NOT DELIVERED FROM ALL SYSTEMS (BUMPER TURRET, GROUND SWEEPS, AND MANUAL METERING CONTROLS) OR SYSTEM DOES NOT SHUT OFF - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 1 Page Navigation
  477    478    479    480    481  482  483    484    485    486    487  
img
DRAFT
TM 5-4210-249-13&P-1
0094
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT03727
Step 27.
Remove driver side crew cab access panel (WP 0499). Remove pump house panel Q
(WP 0540). Disconnect main wire harness pump operator's panel wire harness
connector DO1. With a test lead set, check for continuity across pump operator's panel
wire harness wire 2830 (red) from main wire harness pump operator's panel wire
harness connector DO1, terminal E to pump operator's panel FOAM SYSTEM switch,
terminal.
If there is no continuity, repair wire 2830 in pump operator's panel wire
harness if repairable (TM 9-2320-325-14&P), or replace pump operator's
panel wire harness (WP 0459).
0094-21