0094
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
TFFT03724
Step 24.
Close pump operator's panel housing (WP 0325). Remove skid plate grille (WP 0550).
Disconnect main wire harness main 5 connector. Remove driver side crew cab access
panel (WP 0499). Remove pump house panel Q (WP 0540). Disconnect main wire
harness pump operator's panel wire harness connector DO1. With a test lead set,
check for continuity across wire 2816 (red) from main wire harness main 5 connector,
terminal 6 to main wire harness pump operator's panel wire harness connector DO1,
terminal D.
If there is no continuity, repair wire 2816 in main wire harness if repairable
(TM 9-2320-325-14&P), or replace main wire harness (WP 0455).
0094-18