6-35. IDLER GEARS - Continued
NOTE
Pull to start gear moving must not be less than 0.5
Ib (0.23 kg) or more than 4.0 lbs (1.8 kg).
(19) Wrap cord several times around idler gear
assembly (1) and attach spring scale.
(20) Pull idler gear assembly (1) several times
and record pull required to start gear
moving. Maximum difference between
pulls is 2 Ibs, 11 ounces (1.22 kg).
(21) If difference between pulls does not fall in
correct ranges, replace bearings.
(22) Place idler gear assembly (1) in soft jaw vise.
(23) Remove three screws (14), Iockwashers (15), washers (16), and test fixture plate (13).
(24) Remove nut (12), screw (11), and two test fixture plates (1 and 9).
(25) Remove idler gear assembly (1) from vise.