DRAFT
TM 5-4210-249-13&P-4
FIELD LEVEL MAINTENANCE
ROOF TURRET MOUNTING PLATE REPLACEMENT
INITIAL SETUP:
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Tools and Special Tools
References
Tool Kit, General Mechanic's: Automotive
Equipment Conditions
Materials/Parts
Roof turret automatic drain valve and controls
Adhesive, Sealant, Silicone RTV
Cleaning Compound, Solvent (WP 0625, Item 12)
Locknut (8)
REMOVAL
TFFT00857
1.
Remove locknut (1) and screw (2) from roof turret mounting plate (3) and vehicle. Discard locknut.
NOTE
Silicone seal must be broken prior to removing roof turret mounting plate.
2.
Remove seven locknuts (4), screws (5), and roof turret mounting plate (3) from vehicle. Discard locknuts.
END OF TASK
0565-1