• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
PUMP HOUSE PANELS REPLACEMENT - Continued
PUMP HOUSE PANELS REPLACEMENT - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 3 Page Navigation
  1160    1161    1162    1163    1164  1165  1166    1167    1168    1169    1170  
img
DRAFT
TM 5-4210-249-13&P-3
0540
PUMP PANEL B REMOVAL
TFFT00226
1.
Remove pump panel A (1) from pump panel B (2).
2.
Remove four screws (3), washers (4), receptacle cover (5), and gasket (6) from pump panel B (2).
3.
Remove screw (7) and washer (8) from receptacle (9) and pump panel B (2).
4.
Remove screw (10), receptacle (9), and box (11) from pump panel B (2).
NOTE
Tag and mark wires and connectors prior to removal to ensure proper installation.
5.
Loosen three screws (12) and remove wires (13) from receptacle (9).
6.
Open small compartment door (14) and disconnect connector (15).
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -