SHORELINE INLET RECEPTACLE REPLACEMENT
SHORELINE INLET RECEPTACLE REPLACEMENT - Continued

Maintenance Manual For Tactical Fire Fighting Truck (Tfft) Model M1142 - 3 Page Navigation
  432    433    434    435    436  437  438    439    440    441    442  
img
DRAFT
TM 5-4210-249-13&P-3
0425
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
TFFT01957
NOTE
Tag and mark wires and connectors prior to removal to ensure proper installation.
2.
Remove screw (2) and connector (3) from bottom of crew cab (4).
3.
Disconnect connector (5) under crew cab (4).
TFFT00901
4.
Remove four screws (6), lockwashers (7), washers (8), cover (9), seal (10), and shoreline inlet receptacle (11)
from crew cab (4). Discard lockwashers.
END OF TASK
INSTALLATION
1.
Install shoreline inlet receptacle (11), seal (10), and cover (9) on crew cab (4) with four washers (8),
lockwashers (7), and screws (6).